Severe Vulnerabilities Discovered in GE Medical Devices

CISA has released an advisory for six high-severity CVEs for GE Carescape patient monitors, Apex Pro, and Clinical Information Center systems.

The US Cybersecurity and Infrastructure Agency (CISA) today issued an advisory for six high-severity security vulnerabilities in patient monitoring devices manufactured by GE Healthcare.

These flaws, collectively dubbed "MDhex," could allow an attacker to make changes at the software level of a device and in doing so interfere with its functionality, render it unusable, change alarm settings, or expose personal health information (PHI). Their discovery began with CyberMDX security researchers investigating the CIC Pro, a common product among customers.

The CIC Pro is a workstation that hospital staff use to view their patients' physiological data, waveforms, and demographics. Data is transmitted from multiple patient-side monitors and collected through a shared network. CIC Pro may be used to centrally manage patient monitors for things such as admission, date and time synchronization, and setting alarm limits.

Researchers started the investigation when they noticed CIC Pro devices in the field had open ports running an outdated and potentially problematic version of Webmin. "It was allowing incoming traffic on a range of management ports," says head of research Elad Luz. "With that [discovery], we thought we'd do an in-depth examination of that product ourselves."

Their analysis led to a total of six severe vulnerabilities, as listed in CISA's advisory. Five were assigned a CVSS maximum severity score of 10: CVE-2020-6961, CVE-2020-6963, CVE-2020-6964, CVE-2020-6966, and CVE-2020-6962. The sixth, CVE-2020-6965, was given a high-severity score of 8.5. MDhex was reported to GE on September 18, 2019, and is being formally disclosed today after a period of collaboration among GE, CISA, and CyberMDX to confirm and evaluate the vulnerabilities.

The popular Carescape product line, launched in 2007, has been adopted by hospitals around the world. Products affected by these vulnerabilities include certain versions of the Carescape CIC, Apex Telemetry Server/Tower, Central Station (CSCS) Telemetry Server, B450 patient monitor, B650 patient monitor, and B850 patient monitor. GE did not disclose the number of affected devices; however, CyberMDX believes the installed base is in the hundreds of thousands.

Inside a hospital, these devices are deployed on a network they share with other monitoring equipment, which also consists of vulnerable devices. If a hospital has one of these affected products, they likely have the others, Luz points out.

Each flaw exists in a different aspect of device design and configuration. CVE-2020-6961 is an SSH vulnerability. An SSH server configuration typically holds a file holding public keys of entities authorized to connect. In vulnerable devices, the configuration also has a private key — which is the same across the entire medical product line.

"The same private key is universally shared across an entire line of devices in the CARESCAPE and GE Healthcare family of products," researchers write in a blog post. "Using the private key, an attacker could remotely access and execute code on these devices — potentially comprising the device's very availability as well as the confidentiality and integrity of any data it holds."

The issue of hard-coded credentials also exists in Microsoft Server Message Block vulnerability CVE-2020-6963. Credentials underlying this flaw can be accessed by doing password recovery on the Window XP operating system of affected devices. With these credentials, an attacker could break into other devices. CVE-2020-6964 exists in MultiMouse/Kavoon KM software, which enables remote keyboard, mouse, and clipboard control of a device. The bug could let an attacker abuse this functionality and take over devices without any credential controls to alter device settings and change data.

VNC vulnerability CVE-2020-6966 enables remote control in VNC, a software used for remote desktop access. Credentials for this are insecurely stored and can be found in publicly available and easily searchable product documentation. CVE-2020-6962 pertains to the deprecated version of Webmin (1.2.5) in affected devices, which are exposed to known exploits in the wild.

These vulnerabilities generated the highest scores because they easily allow hackers to do remote code execution, which Luz considers "the endgame" for the majority of cyberattacks.

"Once you gain that remote code execution, you can [alter] the device functionality, perhaps make it unusable, perhaps make it display false data, things like that," he explains. While it's not clear why an attacker might target a specific medical device, the level of access granted by these vulnerabilities could enable a large-scale ransomware attack on a healthcare target.

GE plans to provide patches and additional security information for affected users over the coming months. Users can check its website for more updates or contact the company directly. In the meantime, mitigations are offered in the CyberMDX blog post.

Related Content:

Check out The Edge, Dark Reading's new section for features, threat data, and in-depth perspectives. Today's top story: "The Y2K Boomerang: InfoSec Lessons Learned from a New Date-Fix Problem."

Kelly Sheridan is the Staff Editor at Dark Reading, where she focuses on cybersecurity news and analysis. She is a business technology journalist who previously reported for InformationWeek, where she covered Microsoft, and Insurance & Technology, where she covered financial ... View Full Bio
 

Recommended Reading:

Comment  | 
Print  | 
More Insights
Comments
Newest First  |  Oldest First  |  Threaded View
COVID-19: Latest Security News & Commentary
Dark Reading Staff 9/25/2020
WannaCry Has IoT in Its Crosshairs
Ed Koehler, Distinguished Principal Security Engineer, Office of CTO, at Extreme Network,  9/25/2020
Safeguarding Schools Against RDP-Based Ransomware
James Lui, Ericom Group CTO, Americas,  9/28/2020
Register for Dark Reading Newsletters
White Papers
Video
Cartoon
Current Issue
Special Report: Computing's New Normal
This special report examines how IT security organizations have adapted to the "new normal" of computing and what the long-term effects will be. Read it and get a unique set of perspectives on issues ranging from new threats & vulnerabilities as a result of remote working to how enterprise security strategy will be affected long term.
Flash Poll
How IT Security Organizations are Attacking the Cybersecurity Problem
How IT Security Organizations are Attacking the Cybersecurity Problem
The COVID-19 pandemic turned the world -- and enterprise computing -- on end. Here's a look at how cybersecurity teams are retrenching their defense strategies, rebuilding their teams, and selecting new technologies to stop the oncoming rise of online attacks.
Twitter Feed
Dark Reading - Bug Report
Bug Report
Enterprise Vulnerabilities
From DHS/US-CERT's National Vulnerability Database
CVE-2020-26120
PUBLISHED: 2020-09-27
XSS exists in the MobileFrontend extension for MediaWiki before 1.34.4 because section.line is mishandled during regex section line replacement from PageGateway. Using crafted HTML, an attacker can elicit an XSS attack via jQuery's parseHTML method, which can cause image callbacks to fire even witho...
CVE-2020-26121
PUBLISHED: 2020-09-27
An issue was discovered in the FileImporter extension for MediaWiki before 1.34.4. An attacker can import a file even when the target page is protected against "page creation" and the attacker should not be able to create it. This occurs because of a mishandled distinction between an uploa...
CVE-2020-25812
PUBLISHED: 2020-09-27
An issue was discovered in MediaWiki 1.34.x before 1.34.4. On Special:Contributions, the NS filter uses unescaped messages as keys in the option key for an HTMLForm specifier. This is vulnerable to a mild XSS if one of those messages is changed to include raw HTML.
CVE-2020-25813
PUBLISHED: 2020-09-27
In MediaWiki before 1.31.10 and 1.32.x through 1.34.x before 1.34.4, Special:UserRights exposes the existence of hidden users.
CVE-2020-25814
PUBLISHED: 2020-09-27
In MediaWiki before 1.31.10 and 1.32.x through 1.34.x before 1.34.4, XSS related to jQuery can occur. The attacker creates a message with [javascript:payload xss] and turns it into a jQuery object with mw.message().parse(). The expected result is that the jQuery object does not contain an <a> ...