Siemens Offers Workarounds for Newly Found PLC Vulnerability

An undocumented hardware-based special access feature recently found by researchers in Siemens' S7-1200 can be used by attackers to gain control of the industrial devices.

Siemens recently issued a security advisory with workarounds and mitigations for a vulnerability uncovered by researchers in its S7-1200 programmable logic controllers (PLCs) that could be used to bypass a firmware integrity check to load malware or hijack the industrial processes of the devices.

Researchers from Ruhr University Bochum in Germany found an undocumented hardware-based special access feature in Siemens' S7-1200 PLCs while studying its bootloader, which handles software updates and verifies the integrity of the PLC's firmware when the device starts up.

Ali Abbasi, a research scholar at Ruhr-University Bochum, doctoral student Tobias Scharnowski, and professor Thorsten Holz will present their findings this week in London at Black Hat Europe. The researchers alerted Siemen, which says it plans to fix the flaw.

It's unclear whether the flaw can be fixed in software or if it requires a hardware swap, according to Abbasi, and the researchers are not sure if additional models of the PLC also are affected.

In a statement in response to an inquiry on the nature of the fix, Siemens said it's still working on the issue, pointing to the SSA-686531 advisory it released late last month. "We are in the process of reviewing our product models and will post updates to SSA-686531 if further models are affected," Siemens said. "With respect to a final solution, Siemens experts continue to work on the issue. Siemens provided workarounds and mitigations within the Siemens Security Advisory (SSA-686531) and Siemens will update the document when a final solution is available."

Abassi and his fellow researchers also found that the special access feature in the PLCs could also be used for good: as a forensic tool for defenders. They employed the feature to view the contents of the PLC's memory, so a plant operator could also use it to find malicious code on the device, for example.

Check out The Edge, Dark Reading's new section for features, threat data, and in-depth perspectives. Today's top story: "A Cause You Care About Needs Your Cybersecurity Help."

Kelly Jackson Higgins is the Executive Editor of Dark Reading. She is an award-winning veteran technology and business journalist with more than two decades of experience in reporting and editing for various publications, including Network Computing, Secure Enterprise ... View Full Bio

Comment  | 
Print  | 
More Insights
Comments
Newest First  |  Oldest First  |  Threaded View
HackerOne Drops Mobile Voting App Vendor Voatz
Dark Reading Staff 3/30/2020
Limited-Time Free Offers to Secure the Enterprise Amid COVID-19
Curtis Franklin Jr., Senior Editor at Dark Reading,  3/31/2020
Register for Dark Reading Newsletters
White Papers
Video
Cartoon Contest
Current Issue
6 Emerging Cyber Threats That Enterprises Face in 2020
This Tech Digest gives an in-depth look at six emerging cyber threats that enterprises could face in 2020. Download your copy today!
Flash Poll
State of Cybersecurity Incident Response
State of Cybersecurity Incident Response
Data breaches and regulations have forced organizations to pay closer attention to the security incident response function. However, security leaders may be overestimating their ability to detect and respond to security incidents. Read this report to find out more.
Twitter Feed
Dark Reading - Bug Report
Bug Report
Enterprise Vulnerabilities
From DHS/US-CERT's National Vulnerability Database
CVE-2020-5347
PUBLISHED: 2020-04-04
Dell EMC Isilon OneFS versions 8.2.2 and earlier contain a denial of service vulnerability. SmartConnect had an error condition that may be triggered to loop, using CPU and potentially preventing other SmartConnect DNS responses.
CVE-2020-5348
PUBLISHED: 2020-04-04
Dell Latitude 7202 Rugged Tablet BIOS versions prior to A28 contain a UAF vulnerability in EFI_BOOT_SERVICES in system management mode. A local unauthenticated attacker may exploit this vulnerability by overwriting the EFI_BOOT_SERVICES structure to execute arbitrary code in system management mode.
CVE-2020-8142
PUBLISHED: 2020-04-03
A security restriction bypass vulnerability has been discovered in Revive Adserver version < 5.0.5 by HackerOne user hoangn144. Revive Adserver, like many other applications, requires the logged in user to type the current password in order to change the e-mail address or the password. It was how...
CVE-2020-8143
PUBLISHED: 2020-04-03
An Open Redirect vulnerability was discovered in Revive Adserver version < 5.0.5 and reported by HackerOne user hoangn144. A remote attacker could trick logged-in users to open a specifically crafted link and have them redirected to any destination.The CSRF protection of the “/...
CVE-2020-8147
PUBLISHED: 2020-04-03
Flaw in input validation in npm package utils-extend version 1.0.8 and earlier may allow prototype pollution attack that may result in remote code execution or denial of service of applications using utils-extend.